The Critical Impact of Data Center Hygiene
Mitigate Hardware Risk
Eliminate microscopic contaminants like zinc whiskers and ferrous particles that cause shorts and hardware failures.
Optimize Cooling
Improve airflow and PUE by removing dust from plenums and intakes, ensuring cooling systems work as designed.
Certified Standards
Maintain ISO 14644-1 Class 8 standards for air cleanliness, providing documented proof for audits.
Extend Equipment Life
Dust and debris pulled into servers make fans work harder, trap heat, and shorten component life. Regular cleaning keeps hardware running cooler and more reliably, protecting your capital investment.
What We Clean
Complete Coverage, Floor to Ceiling
Subfloor Plenums
HEPA vacuuming and wipe-down of the underfloor space, including cabling, conduit, and the slab.
Raised Floors
Static-safe cleaning of tiles, stringers, pedestals, and the support grid infrastructure.
Ceiling Plenums
Removal of dust and debris above the ceiling grid that would otherwise circulate back into the room.
Server Cabinets
Interior and exterior cleaning of racks, doors, perforated panels, and cable management systems.
Cooling Equipment
Surface cleaning of CRAC/CRAH unit exteriors and surrounding mission-critical support areas.
Support Spaces
IDF/MDF, telecom, network rooms, UPS, and battery rooms maintained to precise standards.
Zinc Whisker Remediation
Identification and safe removal of conductive zinc whisker contamination from floor tiles and surfaces.
Post-Construction
Final cleaning of new builds so the space is contaminant-free before equipment goes live.
Our Process
01
Site Assessment
We walk the facility, review your requirements, and take baseline particle counts.
02
Custom Cleaning Plan
We build a scope and schedule around your layout, change windows, and security rules.
03
Precision Cleaning
Trained technicians work area by area, from ceiling to subfloor.
04
Verification
Post-clean particle counts confirm results against ISO 14644-1 Class 8.
05
Documentation
You receive a service report with before-and-after photos, findings, and results for your audit and insurance records.
How We Protect Your Live Environment
Live Equipment Safety Protocols During Cleaning
HEPA Filtration
Use of specialized HEPA filtered vacuums that capture 99.97% of particles down to 0.3 microns.
Non-Conductive Materials
Exclusive use of non-conductive, low-moisture cleaning solutions and non-shedding microfibers.
Zero Downtime Commitment
Work is performed while hardware is live and operational, following strict internal SOPs.
ESD Protection
Technicians use Anti-Static/ESD safe equipment to prevent electrostatic discharge near critical components.
Maintenance & Reporting
We will immediately inform you of any issues found while under the floor, such as loose support pedestals, bypassed air, or disconnected cables. Our goal is to prevent the small issues from becoming big problems, while maintaining your critical hygiene standards.
While we're under the floor, we also look for problems you can't see from above such as water leaks, glycol drips, pest activity, and structural issues. Anything we find is documented and reported to you.
Cleaning Programs
Specialized maintenance programs for mission-critical infrastructure.
One-Time Deep Cleaning
A complete reset for facilities that haven't been professionally cleaned recently.
Post-Construction Cleaning
Final cleaning of new data halls and expansions before commissioning.
Recurring Maintenance
Monthly, quarterly, or semi-annual programs that keep contamination under control year-round. How often you need service depends on traffic, filtration, and construction activity, and we'll recommend a schedule that fits your site.
Emergency Response
Rapid cleanup after a leak, construction incident, or contamination event.